- Your one stop shop for KNX devices in the USA 🇺🇸
- (+1) 786 956 6821
- support@knxsupply.com
- Store Location
- Sign in or Register
- Home
-
Categories
- System Devices
- Switching/Shutter Actuators
- Dimming Actuators
- HVAC
- Binary Inputs
- Keypads
- Gateways
- Enclosures and Boxes
- Occupancy Sensors
- Visualization Systems and Touch Panels
- Weather Sensors
- Drivers and ECGs
- Special Sensors
- HVAC
- Accessories
- Cable
- Expert Picks
- KNX Certified Training
- Newest Products
- Best Selling Products
Brands
- Articles
- Contact Us
Your cart is empty
- Home
- All Collections
- SIEMENS
Filter
SIEMENS
Filter
Showing 21 - 39 of 39 items
- Secure KNX/IP Gateway: Enables communication between KNX systems and IP networks with KNX IP Secure encryption.
- Power Over Ethernet (PoE): Can be powered via PoE or an external 24V AC/DC supply.
- Remote Access: Provides secure remote access to KNX systems through VPN connections.
- Multiple Connections: Supports up to five simultaneous KNXnet/IP tunneling connections.
- LED Indicators: Features LEDs for KNX, IP communication, and power status.
- Easy Configuration: Configured through ETS software, supporting secure commissioning.
- Compact Design: Designed for DIN rail mounting, ideal for distribution boards.
- Flexible Power Options: Operates via PoE or separate power supply, ensuring flexibility in installation.
- Direct Mode Pushbutton: The button with an integrated yellow LED toggles between bus mode and direct mode.
- Brief Press Functionality: Pressing the button briefly activates the green LED for 30 seconds, indicating the last selected module (A to E) and the switching state of the outputs (red LEDs on buttons 1 to 3).
- Switching State Indication: The red LEDs in buttons 1 to 3 show the relay contact status: LED ON = contact closed, LED OFF = contact open.
- Activating Direct Mode: Holding the button for at least 3 seconds turns on the yellow LED, indicating that direct mode is now active.
- Output Control in Direct Mode: In direct mode, each output of the currently selected module can be switched on or off via a pushbutton on the top of the main module, using a toggle function.
- Pushbutton Behavior: Pressing the pushbutton once turns the output on if it's off, and pressing it again turns it off. The red LED on the pushbutton shows the current state.
- Unused Buttons: Pushbuttons 4 to 6 and their LEDs are not utilized in the N 513/11 model.
- Module Selection: To change the output state of a different module, the desired module must be selected by pressing the direct mode pushbutton multiple times.
- Device Type: The switching actuator sub-module N 513/21 is a DIN-rail mounted device in N-system dimensions.
- Relay Outputs: It can switch three groups of electrical consumers independently via its three relay contact outputs.
- Load Monitoring: Each relay output features load current measurement and monitoring (load-check).
- Standalone Operation: The sub-module cannot operate independently and must be connected to a main module.
- Connection Method: It connects via a 6-pole bridging connector to a main module (N 513/11, N 512/11, or N 562/11) or to another sub-module already connected to a main module.
- Power Supply: The sub-module’s electronics are powered by bus voltage through the 6-pole bridging connector.
- Modular Extension: Up to 4 sub-modules can be connected in series to a main module, extending it from 3-fold to 15-fold switching capability.
- The sunblind actuator N 523/04 only works together with the application program 25 A4 Venetian blind actuator 981201.
- The Engineering Tool Software (ETS) up from ETS2 V1.3 is required for the parameterisation and for loading the application program.
- This is structured so that there is sufficient basic functionality available in the supplied state for simple applications in combination with 11 basic communication ob-jects: the always available object "Status Direct mode", an alarm object that influences all channels, an object "Blockade" that also influences all channels and the two 1-bit command objects per channel enabling a blind to be moved into the upper or lower final position, to stop the drive and to open or close the slats stepwise.
- When commissioning the sunblind actuator the following objects can be added per channel, if needed, via the parameter tab "Functions, Objects":
- Manages up to 1,250 KNX statuses and values, with easy access via standard web browsers on PCs, tablets, and smartphones.
- Flexible Visualization: Offers graphical and mobile-friendly editors for customizable control and display elements, adaptable to various styles and devices.
- Advanced Automation: Includes timer, scene, and alarm modules, supporting up to 5,000 events and 250 alarms, ensuring robust automation and monitoring.
- IP Integration: Controls up to 20 IP devices and integrates seamlessly with SONOS speakers and Philips HUE lighting systems.
- Efficient Connectivity: Features a 10/100 Mbps Ethernet interface for reliable IP network connections, powered by an external 24V AC/DC source.
- KNX Network Control: Monitors and controls up to 1,250 KNX statuses and values.
- User-Friendly Access: Operates through standard web browsers on PCs, tablets, and smartphones.
- Graphical Customization: Includes web and smart editors for creating customizable visualizations.
The USB-KNX interface OCI702 serves to provide a USB-KNX connection to access tools from a Microsoft Windows PC to a KNX network or individual device. It consists of the OCI702 service interface as well as several connection cables and accessories including cable ties and a service bag.
- Rated voltage: AC 120 V
- Rated current: 20 A
- Number of channels: 8
- Dimensions (W x H x D): 144 x 90 x 60 mm
- Dimension width (1 MW = 18 mm): 8 MW
Mounting plate for presence detector.
- Mounting plate for presence detectors UP 258Dx1 S 258/12
- For mounting presence detector UP 258Dx1 with 4x4 boxes.
- Color white (similar to RAL 9016)
- Dimensions 109x109x11 mm
- Power supply: via KNX Bus line, 20VDC
- Rated voltage: 120V AC +10%/-15%, 50/60 Hz
- Rated current:
- 2-channel: 2x1.3A@cosФ=1.0
- 1-channel: 1x2.2A@cosФ=1.0
- N-system DIN-rail mounted device, width:4MU(1MU=18mm)
- Load output:Lamp type2 channels1 channel
Incandescent lamps 150 W250 WLow voltage halogen lamps
with magnetic transformers
120 VA200 VADimmable LED <= 50 VA<=50 VA
- The DALI push-button input 4-fold flush-mounted 141/71 is a binary input device for insertion into a flush-mounted box.
- The device is powered via the connected DALI cable
- The device offers 4 input channels for potential-free contacts
- Installation switches or installation push-buttons can be connected. The required voltage is supplied by the DALI push-button input 4-fold (no additional voltage source required).
- Triggered by the connected push-buttons or switches, the DALI push-button input 4-fold sends telegrams via the DALI line to a central DALI controller.
- The push button interface is a binary input and output device for installation in in-wall boxes (Æ 60 mm, depth: 40 mm).
- Each of the two channels may be used either as an input for potential-free switch / push button contacts or as an output for control of a light emitting diode (LED).
- The required scanning / control voltage is provided by the push button interface (requires no additional power supply).
- For example, up to 2 switches/push buttons with one potential-free contact each or one 2-fold push button with two potential-free contacts may be connected to a push button interface.
- The connection is carried out via a cable set which is permanently connected to the push button interface.
- The connecting cables between switches/push buttons and the push button interface may be extended up to 10 m. It must be ensured that twisted cable pairs are used.
- Commands can be given to actuators via the connected switches/push buttons, e.g. for defined switching on/off, for dimming fluorescent lamps or for raising/lowering venetian blinds and adjusting the louvres.
- Each channel, which is configured as an output, can drive an output current of up to 2mA for controlling a light emitting diode (LED).
- With the ETS the application program is selected, its parameters and addresses are assigned appropriately, and downloaded to the push button interface.
- The push button interface is a binary input and output devices for installation in in-wall boxes (Æ60 mm, depth: 40 mm).
- Each of the four channels may be used either as an input for potential-free switch / push button contacts or as an output for control of a light emitting diode (LED).
- The required scanning / control voltage is provided by the push button interface (requires no additional power supply).
Presence / Motion detector
- The detector senses the presence of a person or that there is no longer anyone in its detection area.
- The detector signal can be analyzed via two separate communication channels, termed motion detector and presence detector.
- The detection range is identical for all channels. Each channel can be locked individually via objects.
HVAC detector
- The detector has an additional control output for HVAC applications.
- For example, this function can switch systems that are used for heating, ventilating and climate control (HVAC) of the room from “Energy saving mode” in an unused room to “Comfort mode” in an occupied room and back to “Energy saving mode”, when the room is again unoccupied.
- Functionality of the Presence detector / Motion detector / HVAC-detector
- For each detector channel 4 communication objects are available, in sum 12 different communication objects.
- It is possible to send one or two KNX telegrams at the beginning and at the end of a detected presence, according to configuration.
- The values of the communication objects are configured for each functional block (motion detector, presence detector, HVAC-detector) via corresponding parameters.
Presence detector with brightness sensor for detection of motion and presence for ceiling mounting
- Contrast measurement of brightness
- Presence motion detection up to Ø8 m
- Flush mounted installation in ceilings with wall box or clamps
- Integrated IR receiver for IR remote control
Functions with commission with ETS
- Three independent output channels with four commands each in case of motion detection
- Integrated 2-level light controller (switching)
- Integrated constant light level controller for up to five lighting groups including
- Usage of motion detector as standalone mode or extension mode to cover wider areas
- Independent output channel for HVAC applications
Characteristics
- These presence detectors are equipped with an integrated brightness sensor and HVAC sensors that use multiple calibration methods so that they can be adjusted at the particular installation location.
- The maximum detection area is 64 m² for presence and 400 m² for motion.
- The presence detectors capture brightness, humidity, temperature, brightness and CO2 and thus control not only the illumination systems but also ventilation and heating systems.
- Communication is conducted via KNX. All types are designed for mounting on the ceiling.
Characteristics
- These presence detectors are equipped with an integrated brightness sensor and HVAC sensors that use multiple calibration methods so that they can be adjusted at the particular installation location.
- The maximum detection area is 64 m² for presence and 400 m² for motion.
- The presence detectors capture brightness, humidity, temperature, brightness and CO2 and thus control not only the illumination systems but also ventilation and heating systems.
- Communication is conducted via KNX. All types are designed for mounting on the ceiling.
Characteristics
- These presence detectors are equipped with an integrated brightness sensor and HVAC sensors that use multiple calibration methods so that they can be adjusted at the particular installation location.
- The maximum detection area is 64 m² for presence and 400 m² for motion.
- The presence detectors capture brightness, humidity, temperature, brightness and CO2 and thus control not only the illumination systems but also ventilation and heating systems.
- Communication is conducted via KNX. All types are designed for mounting on the ceiling.
Characteristics
- Actively emitted by the ultrasound sensor (US), ultrasound waves (40 kHz) propagate around the rest of the room.
- They envelop objects that are in the room and penetrate into all corners.
- This means that the ultrasound sensor (US) can even detect movements when there is no line-of-sight contact between it and the person.
- This presence detector is equipped with an integrated brightness and temperature sensor.
- The maximum detection area is 28 m² for presence and 79 m² for motion.
- The presence detector captures brightness and temperature data and thus controls not only the illumination systems but also ventilation and heating systems.
- Communication is conducted via KNX. The presence detector is designed for installation in the ceiling.
Presence detector with brightness sensor for detection of motion and presence for ceiling mounting
- Contrast measurement of brightness
- Presence motion detection up to Ø8 m
- Flush mounted installation in ceilings with wall box or clamps
- Integrated IR receiver for IR remote control
Functions with commission with ETS
- Three independent output channels with four commands each in case of motion detection
- Integrated 2-level light controller (switching)
- Integrated constant light level controller for up to five lighting groups including
- Usage of motion detector as standalone mode or extension mode to cover wider areas
- Independent output channel for HVAC applications
Expert picks
$295.00
$45.00
$237.61
Newest Products
$250.00
$20.00
$49.00
KNX Training
$1,500.00
$1,200.00