• Your one stop shop for KNX devices in the USA 🇺🇸
Filter
Availability
Price
$
$
Manufacturer
Product type
+ Show more - Show less

weinzierl

Filter
Showing 21 - 39 of 39 items
KNX IP Router 752 secure
20%

Compact bus powered Router between LAN/Ethernet and KNX bus.

Application area

The compact KNX IP Router 752 secure allows forwarding of telegrams between different lines through a LAN (IP) as a fast backbone.

In addition this device is suited to connect a PC to the KNX network e.g. for ETS programming.

The device supports KNX Security which can be enabled in ETS. 

As secure router the device allows coupling of not secured communication on KNX TP to a secured IP

backbone.

Also for the interface functionality (tunneling) KNX security prevents from unauthorized access.

The IP address can be obtained by a DHCP server or by manual configuration (ETS) respectively.

This device works according to the KNXnet/IP specification using the core, the device management, the tunneling and the routing part.

The KNX IP Router 752 secure has an extended filter table for main group 0..31 and is able to buffer up to 150 telegrams.

Power is supplied via the KNX bus.

KNX Modbus RTU Gateway 886
20%

KNX Modbus Gateway with 250 data points.

Application area

The KNX Modbus RTU Gateway 886 is a compact Gateway between KNX TP and Modbus RTU with 250

freely configurable channels.

The device enables easy integration of Modbus devices that support the RTU protocol via RS-485 and can act as a Modbus master or slave.

As Master the device can address up to 25 slave devices.

The assignment between KNX objects and Modbus registers can be configured via parameters in the ETS

without an additional tool.

The gateway provides a galvanic isolation between KNX bus and Modbus.

Two buttons and three LEDs allow local operation and visualization of the device status.

KNX Modbus TCP Gateway 716
20%

With KNX IP interface, bus powered.

Application area

The KNX Modbus TCP Gateway 716 secure is a compact gateway between KNX TP and modbus TCP with 250 freely configurable datapoints.

The device enables easy integration of modbus devices that support the TCP protocol via IP and can act as a modbus master or slave.

As master the device can address up to 5 slave devices.

The assignment between KNX objects and modbus registers can be configured via parameters in the ETS

without an additional tool.

Two buttons and three LEDs allow local operation and visualization of the device status.

Furthermore, the device can be used as a programming interface to connect one or more PCs to the KNX bus (e.g. for ETS®).

Power is supplied via the KNX bus.

The device supports KNX Security.

KNX Multi IO 570 (TP)
20%

KNX TP Multi IO with 48 configurable In- and Outputs.

Application area

The KNX TP Multi IO 570 is a universal binary interface for building control. 

It provides 48 I/O lines.

Each line can be used as binary input as well as binary output.

The peripherals can be fed by an external voltage of 24 V⎓.

Channels which are configured as inputs can be used to control lights or blinds via the KNX network.

They also can be used to count impulses, e.g. as interface for energy meters. 

Channels which are configured as outputs can directly drive signal LEDs, external coupling relays (e.g.590) or jalousie relays (592).

The integrated USB interface allows establishing a bidirectional connection between a PC and the KNX bus.

The USB connector has a galvanic separation from the KNX bus.

Both ETS (Version 4.2 or later) and visualization tools support this interface.

The configuration of the device is done with ETS, a local download is possible.

An easy to read OLED display on the front panel enables a manual operation to test the installation.

KNX Multi IO 580 (IP)
20%

KNX IP Multi IO with 48 configurable In- and Outputs.

Application area

The KNX IP Multi IO 580 is a universal binary interface for building control.

It provides 48 I/O lines.

Each line can be used as binary input as well as binary output.

The peripherals can be fed by an external voltage of 24 V⎓.

Channels which are configured as inputs can be used to control lights or blinds via the KNX network. 

They also can be used to count impulses, e.g. as interface for energy meters. 

Channels which are configured as outputs can directly drive signal LEDs, external coupling relays (e.g.

590) or jalousie relays (592).

The device works using the medium KNX IP.

It can be configured using the ETS (Version 4.2 or higher) with native parameters and standard group objects.

Also the KNX addressing scheme, based on individual device

address and group objects, is unchanged.

An easy to read OLED display on the front panel enables a manual operation to test the installation.

KNX PowerSupply 365
20%

640 mA Power supply.

Installation Instructions

  • The device may be used for permanent interior installations in dry locations, within distribution boards or small casings with DIN rail.
KNX PowerSupply DGS 366
20%

640 mA Power supply with integrated KNX node, diagnosis and logical functions.

Application area

The KNX PowerSupply DGS 366 is a 640 mA bus power supply with high efficiency and a small footprint of only 4 units (72 mm).

The device has a bus choke and additionally provides an output for auxiliary power.

The integrated KNX node monitors output current, bus voltage and the temperature in the enclosure. Various logic functions are available for application purpose.

The configuration is done with the ETS (version 4.2 or higher).

An easy to read OLED display on the front panel enables the user to display the operating parameters locally on the device.

KNX PowerSupply USB 367
20%

640 mA Power supply with integrated USB interface, KNX node, and diagnosis functions.

Application area

The KNX PowerSupply USB 367 is a 640 mA power supply with an integrated USB interface and a small footprint of only 4 TE (72 mm).

The device has a bus choke and additionally provides an output for auxiliary power.

The USB interface allows establishing a bidirectional connection between a PC and the KNX bus.

The USB connector has a galvanic separation from the KNX bus.

Both ETS (Version 4.2 or later) and visualization tools support this interface.

The KNX node monitors output current, bus voltage and the temperature in the enclosure.

The configuration of the device is done with ETS.

An easy to read OLED display on the front panel enables the user to display the operating parameters locally on the device.

KNX RF USB 340 Stick
20%

Compact USB interface between PC and KNX RF.

Application area

This interface allows establishing a bidirectional connection between a PC or a laptop and the KNX RF wireless network. 

The device complies with the specification of KNX RF and supports the protocol cEMI.

The interface is compatible with ETS 5 (or higher).

For software integration (Windows or Linux) of this interface the free SDK kDrive express is available.

The power is supplied via the USB port.

KNX Serial 870
20%

Serial Interface and ObjectServer for KNX Bus.

Application

The KNX Serial Interface BAOS 870 serves as a simple integration solution for non-KNX devices.

Designed as a RS-232 interface, the KNX Serial BAOS 870 uses the proven FT1.2 protocol (PEI 10) as message format.

Moreover, the device supports the BAOS protocol for accessing data points.

This allows non-KNX devices to be fully integrated into a KNX network via a RS-232 link.

For a quick start, free SDKs, a demonstration tool as well as an ETS entry with 250 group objects are available.

Furthermore, individual ETS representations for OEM versions can be created.

KNX TP LineCoupler 650
20%

Compact KNX Line Coupler.

Application area

The KNX LineCoupler 650 is a KNX line coupler in a compact design.

It connects two KNX bus segments (for example, a KNX line with a KNX area).

The device has an extended filter table for main group 0 … 31 and ensures a galvanic isolation between the lines.

The coupler supports KNX longframes and is compatible with the ETS® software (ETS 4.2 or higher).

The buttons on the front panel allow disabling the telegram filter for testing purposes.

The LEDs indicate operating conditions as well as communication errors on the KNX bus.

The power is supplied via the KNX bus (main line).

KNX TP Push Button 420 secure, double
20%

KNX TP Push Button with KNX Data Security For MATCH 55 series.

Application area

The KNX TP Push Button 420 secure is a push button with integrated bus coupling unit.

The device is available with one or two rockers.

Each rocker offers two pressure points (up/down).

The device is part of the MATCH 55 push button series.

With the supplied installation kit, the push button fits mechanically to numerous switch ranges available on the market with internal dimensions of 55 mm.

The soft and quiet push button operation allows the installation in bedrooms and living rooms.

The application offers extensive functions for switching, dimming, shutter, valuator, scene and color control as well as a sequence controller.

Each button on a rocker can be configured individually.

The flexible operating concept also allows different functions on one button depending on the setting.

The device also contains 10 independent logic or time functions.

The device supports KNX Data Security.

KNX TP Push Button 420 secure, single
20%

KNX TP Push Button with KNX Data Security For MATCH 55 series.

Application area

The KNX TP Push Button 420 secure is a push button with integrated bus coupling unit.

The device is available with one or two rockers. 

Each rocker offers two pressure points (up/down).

The device is part of the MATCH 55 push button series.

With the supplied installation kit, the push button fits mechanically to numerous switch ranges available on the market with internal dimensions of 55 mm.

The soft and quiet push button operation allows the installation in bedrooms and living rooms.

The application offers extensive functions for switching, dimming, shutter, valuator, scene and color control as well as a sequence controller.

Each button on a rocker can be configured individually.

The flexible operating concept also allows different functions on one button depending on the setting.

The device also contains 10 independent logic or time functions.

The device supports KNX Data Security.

KNX TP Push Button Interface 420 secure
20%

KNX TP Push Button Interface with KNX Data Security.

Application area

The KNX TP Push Button Interface 420 secure is a push button interface for the KNX bus.

It is suitable as a binary input for connecting up to four conventional push buttons or potential-free contacts. 

In addition, the device offers two outputs for LEDs. 

A pluggable connection cable is included in the scope of delivery.

The integrated push buttons and LEDs allow a quick test of the configuration.

The application offers extensive functions for switching, dimming, shutter, valuator, scene and color control as well as sequence controllers and scalable pulse counters.

Each channel can be configured individually.

The flexible operating concept also allows different functions on one channel depending on the setting.

In addition, the device contains 10 independent logic or time functions.

The device supports KNX Data Security.

KNX USB Interface 312
20%

Compact USB Interface between PC and KNX bus.

Application area

The KNX USB Interface 312 is a data interface between a PC or laptop and the KNX installation bus.

It can be used as a programming interface for ETS® Software Version 3 (or higher) and supports KNX long frames.

Long telegrams enable a faster download to devices that can receive these telegrams.

The LEDs on the device indicate the operating status and communication errors on the bus.

The USB connector is galvanic isolated from the KNX bus.

KNX USB Interface 332 Stick
20%

Compact USB Interface between PC and KNX bus.

Installation Instructions

  • The device shall be used in indoor areas only.
  •  It can be connected directly to a USB port of a PC or laptop.
  • The KNX connector is marked at the enclosure with +/- for bus polarity.
Multi IO Extension Shutter 592
20%

Blind/Shutter control with one output of a KNX Multi IO.

  • The device may be used for permanent interior installations in dry locations or within distribution boards with DIN rail.
Multi IO Extension Switch 590
20%

Bi-stable coupling relay for KNX Multi IO.

Application area

The Multi IO Extension Switch 590 serves as a power-saving alternative to commercial standard coupling relays.

The coupling relay is controlled as a mono-stable relay, but uses a bi-stable relay internally, thus reducing the holding current by up to 95%.

The Multi IO Extension Switch 590 has an integrated fuse to protect high-quality equipment.

Push Button 436, 24V, double
20%

Push button for extra low voltage for MATCH 55 series.

The 24V Push Button 436 is a push button for direct connection to push button inputs of e.g. smart home control panels, PLC controls or push button interfaces of any bus system.

The device is available with one or two rockers.

Each rocker offers two pressure points (up/down).

A pluggable connection cable is included in the scope of delivery.

The device is part of the MATCH 55 push button series.

With the supplied installation kit, the push button fits mechanically to numerous switch ranges available on the market with internal dimensions of 55 mm.

The push button is characterized by soft and quiet button press.

The optional terminal block enables the screwless connection of cables with a cross section of up to 0.75 mm².